Key features
- 2000 A AC/DC True RMS current through the clamp
- Full-function DMM: V, A, Ω, capacitance, Hz and duty cycle
- Large 2 in (50 mm) jaw for 2000MCM or two 500MCM cables
- 4000-count backlit display for dimly lit areas
- DCA zero, relative mode and data hold
AED 1,365.00excl. 5% VAT
Buy now, or add it to your RFQ list to get a quote together with other items.Bulk and project orders welcome
Could not add to your RFQ list. Please try again.
- Delivery across the UAE
Overview
The Extech 380926 is a 2000 A True RMS AC/DC clamp meter with a built-in full-function digital multimeter. Its rugged 2 in (50 mm) jaw accommodates one 2000MCM or two 500MCM cables, making it suited to heavy industrial power distribution, switchgear, generators, DC systems and large motor feeders.
Beyond high current through the clamp, the autoranging DMM measures AC/DC voltage to 1000 V, current to 400 mA via the test leads with 0.1 µA resolution, resistance, capacitance, frequency, duty cycle, diode and continuity. Readings appear on a large 4000-count backlit display, and the meter offers DCA push-button zero, relative measurements and data hold. The heavy-duty ABS case has a built-in stand and thumb-operated function switch. Rated CAT IV-600V. Supplied with test leads and a 9 V battery.
Features
- 2000 A AC/DC True RMS current through the clamp
- Full-function DMM: V, A, Ω, capacitance, Hz and duty cycle
- Large 2 in (50 mm) jaw for 2000MCM or two 500MCM cables
- 4000-count backlit display for dimly lit areas
- DCA zero, relative mode and data hold
- CAT IV-600V safety rating
Specifications
- Model
- 380926
- Type
- True RMS AC/DC clamp meter with full-function DMM
- AC/DC Current (Clamp)
- 400 A, 2000 A — 0.1 A resolution, ±(2% + 5d)
- AC/DC Current (Test Leads)
- 400 µA, 4000 µA, 40 mA, 400 mA — 0.1 µA resolution, ±(1.2% + 5d)
- DC Voltage
- 400 mV to 1000 V — 0.1 mV resolution, ±(1% + 2d)
- AC Voltage
- 4 V to 1000 V — 1 mV resolution, ±(1.2% + 5d)
- Resistance
- 400 Ω to 40 MΩ — 0.1 Ω resolution, ±(1% + 5d)
- Capacitance
- 50 nF to 50 µF — 10 pF resolution, ±(3% + 5d)
- Frequency
- 5 Hz to 100 kHz — 0.01 Hz resolution, ±(1% + 5d)
- Duty Cycle
- 1% to 99% — 0.1% resolution, ±(1% + 5d)
- Diode / Continuity
- Yes
- Jaw Opening
- 2 in (50 mm) — one 2000MCM or two 500MCM cables
- Display
- 4000-count backlit LCD
- Safety Rating
- CAT IV-600V, CAT III-1000V
- Power
- 9 V battery
- Dimensions / Weight
- 255 × 73 × 38 mm / 380 g
In the box
- 1 × Extech 380926 Clamp Meter
- 1 × Set of test leads
- 1 × 9 V battery